618-599-2748 or 815-739-8374

E2U Polymer Concrete 2 Gal kit

$105.17

E2U Polymer Concrete is a flowable polyurethane concrete installed at 1/8th to 1/4 inch to protect concrete from physical and chemical damage.  It is highly resistant to impact and abrasion.

Questions about this product?
SKU: PC Category:
Description

Description

E2U Polymer Concrete is a flowable polyurethane concrete installed at 1/8th to 1/4 inch to protect concrete from physical and chemical damage.  It is highly resistant to impact and abrasion.  It is unaffected by animal fats and most solvents.  E2U Polymer Concrete has a thermal expansion and contraction similar to concrete which allows it to maintain adhesion when subjected to the hot pressure washed.  It can be used at constant service temperatures up to 220°F.  E2U Polymer Concrete is fast cure and usually installed without a primer or top coat and can be returned to service 12-24 hours after installation.     Typical areas of application are  Commercial kitchens, chemical processing, aircraft hangers, hospitals.

Physical Properties
Solids Content, % …………….. 100
Volumetric Ratio, ……Kit Packaging
Coverage ……………200 -250 SF/gal.
Pot Life, Fast Cure …….. 20 minutes
(Pot Life is reduced by increasing
temperature and/or mass.(75 degrees)

Cure
Dry to Touch ………………. 4 hours
Return to Service ……. 12-24 hours
VOC……………………….. 0 m/l

Colors
1020 Color Line

Limitations
• Do not apply material in direct sunlight or when temperatures are below 45F or above 90F.
• Material will amber when exposed to UV light.
• Topcoat is recommended.

Performance Properties

Performance Properties

Tensile Strength, psi (ASTM D-638)………………………… 880
Ultimate Compressive Strength, psi (ASTM D-695) ……………9,260
Ultimate Flexural Strength, psi (ASTM D-790) …………….. 3,009
Hardness, Shore D (ASTM D-2240) ……………………….. 83
Adhesion to Concrete (ASTM 451) ……………..
concrete fails before loss of bond…< 500……

Chemical Resistance

Chemical Resistance

General Information

Surface Preparation

Concrete surfaces must be clean, dry, and structurally sound. Surface must be shot blasted or scarified to CSP 3 to CSP 5. Priming of concrete substrates is not usually required under typical circumstances. However, due to variations in concrete quality, surface conditions, surface preparation and ambient conditions, reference test areas are recommended to determine whether priming is required to prevent the possibility of blisters, pinholes and other aesthetic variations. If priming is required, use E2U WB Epoxy Preimer applied at the rate of 200-300 sq. ft. per gallon. Proceed with E2U PolyCrete SL when primed surface has become tack-free.

Moisture Vapor Emissions Precautions

Moisture Vapor Emissions Precautions

All interior concrete floors not poured over an effective moisture vapor retarder are subject to possible moisture vapor transmission that may lead to blistering and failure of the coating system. It is the coating applicator’s responsibility to conduct calcium chloride and relative humidity probe testing to determine if excessive levels of vapor emissions are present before applying any coatings. E2U can supply moisture remediation products. Consult our technical service department. E2U and its sales agents will not be responsible for coating failures due to undetected moisture vapor emissions.

Mixing Instructions

Mixing Instructions

Pour entire contents of parts A, B and C into mixing container and mix for 30 seconds. Then slowly add part D (color) over a period of about 15 seconds. Once all of the components are incorporated, mix for an additional 30 seconds. Mixing should be done with a Kohl type mixer or any other mixer designed to mix heavy mortars. Mixed material should be used immediately. It is recommended that multiple mixing containers be used to insure an adequate supply of fresh material.

Application Recommendations

Application Recommendations

E2U Polymer Concrete can be applied directly to the concrete without a primer. However, if the concrete is excessively porous, using E2U WB Epoxy as a primer can reduce outgassing, pinholes or blisters. A gauge rake will be required for large areas. Once the slurry is raked to the desired thickness, immediately roll the surface with a looped roller or spiked roller to remove any imperfections and bring the resin to the top. It is very important to keep a wet edge. Each batch must be placed within 10 minutes of the prior one. Failure to due this could result in a visible tie in line.

Coverage per kit is as follows

Coverage per kit is as follows

Handling Precautions

Handling Precautions

Avoid contact with skin; wear protective gloves. Read Material Safety Data Sheet before using.

Slip and Fall Precautions

Slip and Fall Precautions

OSHA and the American Disabilities Act (ADA) have now set enforceable standards for slip resistance on pedestrian surfaces. The current coefficient of friction required by ADA is .6 on level surfaces and .8 on ramps. E2U recommends the use of angular slip-resistant aggregate in all coatings or flooring systems that may be exposed to wet, oily or greasy conditions. It is the contractor and end users’ responsibility to provide a flooring system that meets current safety standards. E2U or its sales agents will not be responsible for injury incurred in a slip and fall accident.

DATASHEET & MSDS

Download Datasheet

Polymer Concrete Datasheet