E2U Epoxy is a two component, high performance modified cycloaliphatic epoxy concrete floor coating system. Its epoxy chemistry provides excellent bonding characteristics. It can be applied as a 12 to 50 mil coating system.

Clear
Questions about this product?
SKU: N/A Categories: ,
Description

Description

E2U Epoxy is a two component, high performance modified cycloaliphatic epoxy concrete floor coating system. Its epoxy chemistry provides excellent bonding characteristics. It can be applied as a 12 to 50 mil coating system. Paint Chips or Color Quartz can be broadcast into E2U Epoxy to create a custom look. Its design features provide for the highest industrial and commercial demands.

Physical Properties

Volumetric Ratio:  .. .. . . . . . . . . . . . .2 to 1
Solids . . . . . . . 100% (+ or – 1%)
Coverage . . . . . . . 100 SF/gal. at 16 mil
. . . . . . .200 SF/gal. at 8 mil
Application Temperature . . . . .  . . . . . .. . . 55-90°F
Thinning . . . .  . . . . . . Not Required
Pot life. . . . . . .  . . . . . . 20-30 min.
Cure Time . . . .  .  . 12 hours (walking . . . . . .        24 hours (light traffic)
Full Cure . . . . . .   . . . . . 5 to 7 days
Critical Re-Coat Time . . . . . .  . . . . . . . . 12 hrs.
Shelf Life . . . . . . . . . . .  . 12 months
USDA Food & Beverage . . . . . . . . .  . . . Meets Req.

Color Pigments
E2U Epoxy is available with standard premixed colors or in clear base with pourable pigment color kits.

Stock Pigments Include:

Clear Beige
Light Gray Tile Red
Medium Gray Safety Red
Dark Gray Safety Blue
White Safety Green
Black Safety Yellow
Tan

Note: Color kits provide the user with stock versatility. By broadcasting Paint Chips or Silica Sand, endless color and texture combinations can be created. Custom colors are available at an additional charge.

Packaging
1.5 Gallon Kits:
Part A . . . . . . . . . . . . . . . . . . . . . . . . . . . 1gal.
Part B. . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2 gal.
15 Gallon Kits:
Part A . . . . . . . . . . . . . . . . . . . . . . . . . . 10 gal.
Part B. . . . . . . . . . . . . . . . . . . . . . . . . . . .5 gal.
PRODUCT LIMITATIONS
Ground level concrete slabs emit invisible moisture vapor. The allowable moisture emissions for concrete are 3 lbs / 1,000 SF over a 24 hour period. If moisture is above this level, then blistering and delamination of coating may occur. A calcium chloride test should be preformed to determine concrete moisture level. If moisture levels exceed the 3 lb. limit, a concrete moisture vapor control system should be used first before applying coating system. Please contact the technical department for approved systems. Coating systems are susceptible to cracking if the concrete moves or separates below the coating. Hence, joint and crack treatment should be reviewed prior to coating application.

As a general rule, control joints (saw cuts) and random cracks should be saw cut or chased first then filled with Easy Patch or similar approved hard epoxy product. Construction joints (two slabs which meet and hence move) should be treated. After the coating has been applied and cured, saw cut through the coating over construction joints and apply an elastodynamics caulking.

WARRANTY
E2U products are warranted for one year after date of application. Please refer to the Limited Material warranty for additional clarification.
SAFETY
Consult material safety data sheet. Avoid contact with skin. Some individuals may be allergic to epoxy resin. Protective gloves and clothing are recommended.
Applications

Applications

The uniqueness and universality of E2U Epoxy’s chemistry facilitates the applications where USDA Food & Beverage and other regulatory requirements must be obtained. i.e. food manufacturing and preparation, pharmaceutical manufacturing and dispensaries, clean rooms, commercial kitchens, laboratories and more. Other areas of use include: garage floors, rest rooms, manufacturing facilities, automotive showrooms and schools.

Advantages

Advantages

Essentially odorless Self-priming over properly prepared substrate
VOC Compliant High color stability
High gloss Withstands medium traffic as thin as 12 mil
Chemically resistant No amine blush
Physical Properties

Physical Properties

PROPERTY VALUE REFERENCE
Compressive Strength 7,800 psi ASTM C 695
Flexural Strength 3,700 psi ASTM D 790
Tensile Strength 3,900 psi ASTM D 638
Bond to Concrete 350 psi ASTM D 4541 Concrete fails at this point
Taber Abrasion 75-80 Mgs ASTM D 4060
Flammability Self-extinguishing
Hardness, Shore D 84 ASTM D 2240
Flash Point 200°F
Concrete Preparation

Concrete Preparation

Before coating is applied, concrete must be:
• Dry – No wet areas
• Clean – Contaminants removed
• Profiled – Surface etched
• Sound – All cracks and spalled areas repaired
Note: Mechanical preparation is the preferred method of preparing concrete for coating application. Shot-blasting, diamond grinding, scarifying and scab- bling are all acceptable methods.

Patching

Patching

Voids, cracks and imperfections will be seen in finished coating if the concrete is not patched correctly. Patch concrete with Easy Patch. After the patching material is cured, diamond grind patch. If a non-patching material is used, contact a technical representative for a compatible and approved alternative.

Testing

Testing

All surfaces are not the same. It is recommended that a sample area be done before the start of the project. The test should be done on-site, using the pro- posed method by the assigned applicator to insure proper adhesion and color. A sample area should also be done on any existing coatings to determine if any contaminants exist or if delaminating will occur.

Mixing

Mixing

The ratio of Top Shelf Epoxy is 2 to 1. That is, two parts A (resin) to one part B (hardener). Mix the following with a drill and mixing paddle. Note: If using a drill mixer, use a low speed (not to exceed 300 rpm) to prevent air entrapment.
1. Premix 1 gallon of Part A for 30-45 seconds.
2. Add 1/2 gallon of Part B and mix for another 60-90 seconds.
3. E2U Epoxy is designed to be immediately poured on the floor. Leaving mixed product in the container will greatly reduce pot life. Once poured out on the floor, 20-30 minutes of working time can generally be expected.

Clean Up

Clean Up

E2U Epoxy, while in an un-reacted state, may be cleaned up with hot water and degreaser. Isopropyl alcohol or acetone may be needed once the resin begins hardening. Lastly, a strong solvent like methylene chloride may be required if resin is nearly set up.

Application Instructions

Application Instructions

Application of E2U Epoxy for a nominal 20 to 30 mil coating system is applied in two coats and in one pass as a top coat. For estimation purposes, use 200 SF per gallon in either case.
1. Always apply in descending temperatures. Concrete is porous and traps air. In ascending temperatures (generally mornings) the air expands and can cause out gassing in the coating. It is safer to apply coatings in the late afternoon, especially for exterior applications.
2. Optimum ambient temperature should be between 55-90°F during application. Note: Cure times are affected by ambient and slab temperatures. Temperatures of 55°F and lower can slow cure times. Temperatures of 85°F and higher will speed up working and times.
3. Mix three gallons of resin using above mixing instructions.
4. Apply approximately 200 SF per gallon (150 SF per gallon for a top coat over Industrial Quartz systems) by immediately pouring out on surface in a ribbon, while walking and pouring at the same time until bucket is empty.
5. Using a squeegee on a pole, pull E2U Epoxy over substrate. As a first coat over bare concrete, pull resin as thin as possible while still wetting out concrete and uniformly covering surface. This allows trapped air to escape more easily. To apply in a single coat over an Industrial Epoxy system, pull at about 200 SF per gallon.
6. Using a 3/8” non-shedding phenolic (plastic) core paint roller, roll coating for- wards and backwards.
7. Lastly, back roll in the opposite direction as step 6.
8. Apply second coat by repeating steps 1-7 the within 12 hours. Failure to re- coat during this window may result in fish eyes. Always sand floor after 12 hours before recoat.

Chip/Silica Sand Broadcast Instructions

Chip Broadcast
1. Following Step 6 above. Broadcast Color Chips/Micro Chips (at 16 lbs. per 100 sq. ft.) by tossing them into the air and allowing them to gently rain down into the wet resin.
2. For a random broadcast, use 1 lb. of chips per 100 sq. ft..
3. Allow to cure. Then scrape the basecoat with a drywall scraper in all directions. Vacuum small pieces and dust.
Silica Sand Broadcast
1. Following Step 6 above, gently throw the silica sand up into the air, allowing it to fall without lumping in one spot or moving the resin. Do this until the floor is totally saturated with the silica sand and the resin will not accept any more. This generally requires 1/2 to 3/4 lbs. per sq. ft.. Allow to dry for 6-8 hours.
4. Sweep floor and stone any high spots.
5. Following either method, apply seal coat of E2U Epoxy/Polyaspartic 100 at approx. 150 sq. ft. per gallon.